        EM427 CT 120/240V 1.5(6)A  single phase three wire digital  smart electricity meter

                                                    2S kWh meter 

           

Main Functions and features:

Measuring Function
Meter can measure import active energy , export active energy , Bi-directional reactive measuring .With time-division measurement function, user can store or calculate active and reactive energy according to the time interval of4 tariffs ( Sharp, peak, Even, valley).


Demand function
Measuring the date and time of bi-direction and different time maximum demand, also store the data of time scales.Max demand can be set by slip Frequency, demand interval and slip Frequency time can be setup .


TOU function
The internal clock circuit of energy meter has time automatic switching function.
Calendar, clock and rate can be set and adjustment through RS485, infrared interface.
At least 4 tariffs and 12 time interval can be set within a natural day, min time interval is 15 minutes. 
It can store 12 account months of two directions, total active energy data and bi-directional reactive energy data.
Data restore time is at 0’clock the end of a month or any day of a month from 1~28 on hour.It can store 12 account months of two way Max demand and date, time


Electricity parameters measurement
Measure record and display voltage, current, active power, reactive power, apparent Power and power factors. error is not more than ±1%.



Summer/winter time switch permit/prohibition
Smart meter provide automatic summer/winter time switch accomplished at 02.00 on the last Sunday of March(forward 1 hours) and at 03:00 on the last Sunday of October(back 1 Hours).

Summer/winter time switch can permit or prohibition by RS485 or IR port.

Communication Function
With an infrared COM and a RS485 COM. Its physical layers are independent with each other. One communication channel will not be affected by the other one.Communication protocols fit Modbus RTU standard.RS485 circuit and energy meter internal circuit can realize electricalisolation and failure protection of circuit.
RS485 communications transfer rates allow selected at 1200bps, 2400bps, 4800 bps and 9600bps, default is 9600bps.
Using communication function , the smart meter can connection to the Fineco Cloud.The reading can be viewed through the web browse at any time.

Pulse output function
Smart meter is equipped with a pulse output which is fully separated from the inside circuit. That generates pulses in proportion to the measured energy .include the testing pulse output of active energy and reactive energy. 14/ 15 Test pulse output contact (P+/P-),13/ 15 Test pulse output contact (Q+/Q-)


Alarm function
When the meter connect wire wrong example: when current connection is reverse the ALARM led will be on.

CT rated setting function
Press “Pagedown” and “pageup” buttons to select the CT transformation ratio press “SET” button to save the setup.

                    

                                 

CT specification
   CT specification please browse:

http://www.fineco.cn/Split-Core-Current-Transformer-5A-1A-output-pd6187574.html


Specification

 

Size &wiring diagram

Wiring diagrams:

 3 Wire  meter with RS485: 

                                  
                        
 wire meter with RS485 :

                                   

 

Download

EM4374 Multichannel Energy Meter~multi Circuit Energy Meter~power Clamp Meter

EM4373 CT 3*230/400V 0.05~5(6)A Three Phase ~Modbus ~ Smart Power Analyzer

EM4372 5(65)A three phase ~ 65A ~Modbus ~ Smart Power analyzer

EM4371 0.33V three phase ~333mV~RS485~S0~DO~Dual source tariff energy Meter for Solar System Home

EM4370 5(65)A three phase ~ 65A ~Modbus ~ import export for PV solar